Solaris prtdiag output

Vikrant posted a comment on my previous post on getting hardware information in Solaris asking if I could explain the output of the prtdiag command in Solaris. Unfortunately the output varies quite a bit depending on what hardware you have, but here’s the output from my Ultra10.

$ /usr/platform/`uname -i`/sbin/prtdiag
System Configuration: Sun Microsystems sun4u Sun Ultra 5/10 UPA/PCI (UltraSPARC-IIi 440MHz)
System clock frequency: 110 MHz
Memory size: 1024 Megabytes

========================= CPUs =========================

Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask
--- --- ------- ----- ------ ------ ----
0 0 0 440 2.0 12 9.1

========================= IO Cards =========================

Bus# Freq
Brd Type MHz Slot Name Model
--- ---- ---- ---- -------------------------------- ----------------------
0 PCI-1 33 1 ebus
0 PCI-1 33 1 network-SUNW,hme
0 PCI-1 33 2 SUNW,m64B ATY,GT-C
0 PCI-1 33 3 ide-pci1095,646
0 PCI-2 33 2 pci108e,1000-pci108e,1000
0 PCI-2 33 2 SUNW,hme-pci108e,1001 SUNW,qsi-cheerio

No failures found in System
===========================

The “System Configuration” line shows vendor and model information as well as the processor version and speed. “System clock frequency” is the bus speed on the motherboard of the system. The processor speed is typically a multiple of the clock frequency.

The “Memory size” shows the total memory in the system. On most server-class systems there is additional output to show what size memory modules are in each slot in the system. This can be very useful for determining if memory can be added or if it will need to go in place of existing chips.

The “CPU” section has detailed information on each processor in the system. Again, this is far more interesting in a larger, multi-processor system. All the processors in a machine should have identical information. I don’t believe Sun systems allow mixing different processors.

The “I/O Cards” section will have information on cards added to the system but may also list I/O devices (drive controllers etc.) built into the motherboard.

So that’s the highlights. If anyone wants to send me the prtdiag output from a larger system I’ll gladly add that here with some details.

sun, solaris, system administration, sysadmin, unix

9 thoughts on “Solaris prtdiag output”

  1. Here is part of a prtdiag from a SunFire E12k showing different processors in the domain. The processors in a uniboard (4 CPUs and associated memory) have to be the same but you can mix CPU classes as shown.

    This is not necessarily recommended; note that on Solaris 8, we had to throttle down the US IV chips to 1050 MHz in order to make it work.


    prtdiag -v:
    System Configuration: Sun Microsystems sun4u Sun Fire 15000
    System clock frequency: 150 MHz
    Memory size: 53248 Megabytes

    ========================= CPUs =========================

    CPU Run E$ CPU CPU
    Slot ID ID MHz MB Impl. Mask
    -------- ------- ---- ---- ------- ----
    /SB00/P0 0 1200 8.0 US-III+ 11.0
    /SB00/P1 1 1200 8.0 US-III+ 11.0
    /SB00/P2 2 1200 8.0 US-III+ 11.0
    /SB00/P3 3 1200 8.0 US-III+ 11.0
    /SB01/P0 32 1200 8.0 US-III+ 11.0
    /SB01/P1 33 1200 8.0 US-III+ 11.0
    /SB01/P2 34 1200 8.0 US-III+ 11.0
    /SB01/P3 35 1200 8.0 US-III+ 11.0
    /SB05/P0 160,164 1050 16.0 US-IV 2.3
    /SB05/P1 161,165 1050 16.0 US-IV 2.3
    /SB05/P2 162,166 1050 16.0 US-IV 2.3
    /SB05/P3 163,167 1050 16.0 US-IV 2.3
    /SB06/P0 192,196 1050 16.0 US-IV 2.3

  2. Many thnaks!
    here is the output from a 2 CPU 280R and a 4 CPU 880.
    cheers
    Pino
    ********************************************
    /usr/platform/SUNW,Sun-Fire-280R/sbin/prtdiag
    System Configuration: Sun Microsystems sun4u Sun Fire 280R (2 X UltraSPARC-III+)
    System clock frequency: 150 MHz
    Memory size: 4096 Megabytes

    ========================= CPUs ===============================================

    Run E$ CPU CPU
    Brd CPU MHz MB Impl. Mask
    — — —- —- ——- —-
    A 0 900 8.0 US-III+ 2.3
    B 1 900 8.0 US-III+ 2.3

    ========================= Memory Configuration ===============================

    Logical Logical Logical
    MC Bank Bank Bank DIMM Interleave Interleaved
    Brd ID num size Status Size Factor with
    —- — —- —— ———– —— ———- ———–
    CA 0 0 2048MB no_status 1024MB 2-way 0
    CA 0 2 2048MB no_status 1024MB 2-way 0

    ========================= IO Cards =========================

    Bus Max
    IO Port Bus Freq Bus Dev,
    Brd Type ID Side Slot MHz Freq Func State Name Model
    —- —- —- —- —- —- —- —- —– ——————————– ———————-
    I/O PCI 8 B 4 33 33 1,0 ok pci108e,1000-pci108e,1000.1
    I/O PCI 8 B 4 33 33 1,1 ok SUNW,hme-pci108e,1001 SUNW,qsi-cheerio

    *******************
    $ /usr/platform/`uname -i`/sbin/prtdiag
    System Configuration: Sun Microsystems sun4u Sun Fire 880
    System clock frequency: 150 MHz
    Memory size: 8192 Megabytes

    ========================= CPUs ===============================================

    Run E$ CPU CPU
    Brd CPU MHz MB Impl. Mask
    — —– —- —- ——- —-
    A 0 900 8.0 US-III+ 2.3
    B 1 900 8.0 US-III+ 2.3
    A 2 900 8.0 US-III+ 2.3
    B 3 900 8.0 US-III+ 2.3

    ========================= Memory Configuration ===============================

    Logical Logical Logical
    MC Bank Bank Bank DIMM Interleave Interleaved
    Brd ID num size Status Size Factor with
    —- — —- —— ———– —— ———- ———–
    A 0 0 512MB no_status 256MB 8-way 0
    A 0 1 512MB no_status 256MB 8-way 0
    A 0 2 512MB no_status 256MB 8-way 0
    A 0 3 512MB no_status 256MB 8-way 0
    B 1 0 512MB no_status 256MB 8-way 1
    B 1 1 512MB no_status 256MB 8-way 1
    B 1 2 512MB no_status 256MB 8-way 1
    B 1 3 512MB no_status 256MB 8-way 1
    A 2 0 512MB no_status 256MB 8-way 0
    A 2 1 512MB no_status 256MB 8-way 0
    A 2 2 512MB no_status 256MB 8-way 0
    A 2 3 512MB no_status 256MB 8-way 0
    B 3 0 512MB no_status 256MB 8-way 1
    B 3 1 512MB no_status 256MB 8-way 1
    B 3 2 512MB no_status 256MB 8-way 1
    B 3 3 512MB no_status 256MB 8-way 1

    ========================= IO Cards =========================

    Bus Max
    IO Port Bus Freq Bus Dev,
    Brd Type ID Side Slot MHz Freq Func State Name Model
    —- —- —- —- —- —- —- —- —– ——————————– ———————-
    I/O PCI 9 B 4 33 33 4,0 ok pci108e,1000-pci108e,1000.1
    I/O PCI 9 B 4 33 33 4,1 ok SUNW,hme-pci108e,1001 SUNW,qsi-cheerio
    I/O PCI 9 A 8 66 66 1,0 ok SUNW,qlc-pci1077,2300.1077.106.1+
    I/O PCI 9 A 7 66 66 2,0 ok SUNW,qlc-pci1077,2300.1077.106.1+

    No failures found in System
    ===========================

  3. SunFire V480

    Looks very much like 880

    SunOS 5.9

    # /usr/platform/`uname -i`/sbin/prtdiag
    System Configuration: Sun Microsystems sun4u Sun Fire 480R
    System clock frequency: 150 MHz
    Memory size: 8192 Megabytes

    ========================= CPUs ===============================================

    Run E$ CPU CPU
    Brd CPU MHz MB Impl. Mask
    — — — —- ——- —-
    A 0 900 8.0 US-III+ 2.3
    A 2 900 8.0 US-III+ 2.3
    B 1 900 8.0 US-III+ 2.3
    B 3 900 8.0 US-III+ 2.3

    ========================= Memory Configuration ===============================

    Logical Logical Logical
    MC Bank Bank Bank DIMM Interleave Interleaved
    Brd ID num size Status Size Factor with
    — — —- —— ———– —— ———- ———–
    A 0 0 512MB no_status 256MB 8-way 0
    A 0 1 512MB no_status 256MB 8-way 0
    A 0 2 512MB no_status 256MB 8-way 0
    A 0 3 512MB no_status 256MB 8-way 0
    A 2 0 512MB no_status 256MB 8-way 0
    A 2 1 512MB no_status 256MB 8-way 0
    A 2 2 512MB no_status 256MB 8-way 0
    A 2 3 512MB no_status 256MB 8-way 0
    B 1 0 512MB no_status 256MB 8-way 1
    B 1 1 512MB no_status 256MB 8-way 1
    B 1 2 512MB no_status 256MB 8-way 1
    B 1 3 512MB no_status 256MB 8-way 1
    B 3 0 512MB no_status 256MB 8-way 1
    B 3 1 512MB no_status 256MB 8-way 1
    B 3 2 512MB no_status 256MB 8-way 1
    B 3 3 512MB no_status 256MB 8-way 1

    ========================= IO Cards =========================

    Bus Max
    IO Port Bus Freq Bus Dev,
    Type ID Side Slot MHz Freq Func State Name Model
    —- —- —- —- —- —- —- —– ——————————– ———————-
    PCI 8 B 2 33 33 2,0 ok pci-pci8086,b154.0/scsi (scsi) PCI-BRIDGE
    PCI 8 B 2 33 33 4,0 ok scsi-pci1077,1016/sd (block) QLGC,ISP10160/pci-brid+
    PCI 8 B 2 33 33 5,0 ok scsi-pci1077,1016/sd (block) QLGC,ISP10160/pci-brid+
    PCI 8 B 5 33 33 5,0 ok SUNW,XVR-100 SUNW,375-3126
    PCI 8 A 0 66 66 1,0 ok QLGC,qla-pci1077,100.1077.100.2/+
    PCI 8 A 1 66 66 2,0 ok QLGC,qla-pci1077,100.1077.100.2/+

  4. Here is the output from a 420r
    System Configuration: Sun Microsystems sun4u Sun Enterprise 420R (2 X UltraSPA RC-II 450MHz)
    System clock frequency: 113 MHz
    Memory size: 4096 Megabytes

    ========================= CPUs =========================

    Run Ecache CPU CPU
    Brd CPU Module MHz MB Impl. Mask
    — — ——- —– —— —— —-
    0 1 1 450 4.0 US-II 10.0
    0 2 2 450 4.0 US-II 10.0

    ========================= IO Cards =========================

    Bus Freq
    Brd Type MHz Slot Name Model
    — —- —- ———- —————————- ——————–
    0 PCI 33 On-Board network-SUNW,hme
    0 PCI 33 On-Board scsi-glm/disk (block) Symbios,53C875
    0 PCI 33 On-Board scsi-glm/disk (block) Symbios,53C875
    0 PCI 33 pcib slot 2 pci-pci1011,25.4/pci108e,100+ pci-bridge
    0 PCI 33 pcib slot 2 SUNW,qfe-pci108e,1001 SUNW,pci-qfe
    0 PCI 33 pcib slot 2 SUNW,qfe-pci108e,1001 SUNW,pci-qfe
    0 PCI 33 pcib slot 2 SUNW,qfe-pci108e,1001 SUNW,pci-qfe
    0 PCI 33 pcib slot 2 SUNW,qfe-pci108e,1001 SUNW,pci-qfe
    0 PCI 33 pcib pci-pci8086,b154.0/scsi (scs+ pci-bridge
    0 PCI 33 pcib scsi-pci1077,1016/sd (block) QLGC,ISP10160
    0 PCI 33 pcib scsi-pci1077,1016/sd (block) QLGC,ISP10160
    0 PCI 33 pcia slot 1 SUNW,m64B SUNW,370-4362

    No failures found in System
    ===========================

  5. System Configuration: Sun Microsystems sun4u Sun Fire V1280
    System clock frequency: 150 MHZ
    Memory size: 24GB

    ======================================= CPUs =======================================
    E$ CPU CPU Temperature Fan
    CPU Freq Size Impl. Mask Die Ambient Speed Unit
    —— ——– ———- —— —- ——– ——– —– —-
    SB0/P0 900 MHz 8MB US-III+ 2.3 49 C 28 C
    SB0/P1 900 MHz 8MB US-III+ 2.3 47 C 28 C
    SB0/P2 900 MHz 8MB US-III+ 2.3 46 C 25 C
    SB0/P3 900 MHz 8MB US-III+ 2.3 46 C 27 C
    SB2/P0 900 MHz 8MB US-III+ 2.3 46 C 25 C
    SB2/P1 900 MHz 8MB US-III+ 2.3 46 C 26 C
    SB2/P2 900 MHz 8MB US-III+ 2.3 48 C 26 C
    SB2/P3 900 MHz 8MB US-III+ 2.3 48 C 26 C
    SB4/P0 900 MHz 8MB US-III+ 2.3 45 C 27 C
    SB4/P1 900 MHz 8MB US-III+ 2.3 49 C 28 C
    SB4/P2 900 MHz 8MB US-III+ 2.3 51 C 27 C
    SB4/P3 900 MHz 8MB US-III+ 2.3 47 C 28 C

    ==================================== IO Devices ====================================
    Bus Freq
    Brd Type MHz Slot Name Model
    — —- —- ———- —————————- ——————–
    0 pci 66 PCI5 SUNW,qlc-pci1077,2300 (scsi-+
    0 pci 33 PCI4 SUNW,qlc-pci1077,2312 (scsi-+
    0 pci 66 1 pci108e,abba (network) SUNW,pci-ce
    0 pci 66 2 scsi-pci1000,21 (scsi-2)
    0 pci 66 2 scsi-pci1000,21 (scsi-2)
    0 pci 66 2 pci108e,abba (network) SUNW,pci-ce
    0 pci 33 3 pci1095,646 (ide)
    0 pci 33 4 bootbus-controller-sgsbbc SUNW,sgsbbc

    =============================== Memory Configuration ===============================
    Segment Table:
    ———————————————————————–
    Base Address Size Interleave Factor Contains
    ———————————————————————–
    0x0 8GB 16 BankIDs 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
    0x2000000000 8GB 16 BankIDs 32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47
    0x4000000000 8GB 16 BankIDs 64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79

    Bank Table:
    ———————————————————–
    Physical Location
    ID ControllerID GroupID Size Interleave Way
    ———————————————————–
    0 0 0 512MB 0
    1 0 1 512MB 4
    2 0 0 512MB 8
    3 0 1 512MB 12
    4 1 0 512MB 1
    5 1 1 512MB 5
    6 1 0 512MB 9
    7 1 1 512MB 13
    8 2 0 512MB 2
    9 2 1 512MB 6
    10 2 0 512MB 10
    11 2 1 512MB 14
    12 3 0 512MB 3
    13 3 1 512MB 7
    14 3 0 512MB 11
    15 3 1 512MB 15
    32 8 0 512MB 0
    33 8 1 512MB 4
    34 8 0 512MB 8
    35 8 1 512MB 12
    36 9 0 512MB 1
    37 9 1 512MB 5
    38 9 0 512MB 9
    39 9 1 512MB 13
    40 10 0 512MB 2
    41 10 1 512MB 6
    42 10 0 512MB 10
    43 10 1 512MB 14
    44 11 0 512MB 3
    45 11 1 512MB 7
    46 11 0 512MB 11
    47 11 1 512MB 15
    64 16 0 512MB 0
    65 16 1 512MB 4
    66 16 0 512MB 8
    67 16 1 512MB 12
    68 17 0 512MB 1
    69 17 1 512MB 5
    70 17 0 512MB 9
    71 17 1 512MB 13
    72 18 0 512MB 2
    73 18 1 512MB 6
    74 18 0 512MB 10
    75 18 1 512MB 14
    76 19 0 512MB 3
    77 19 1 512MB 7
    78 19 0 512MB 11
    79 19 1 512MB 15

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    0 0 SB0/P0/B0/D0,SB0/P0/B0/D1,SB0/P0/B0/D2,SB0/P0/B0/D3
    0 1 SB0/P0/B1/D0,SB0/P0/B1/D1,SB0/P0/B1/D2,SB0/P0/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    1 0 SB0/P1/B0/D0,SB0/P1/B0/D1,SB0/P1/B0/D2,SB0/P1/B0/D3
    1 1 SB0/P1/B1/D0,SB0/P1/B1/D1,SB0/P1/B1/D2,SB0/P1/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    2 0 SB0/P2/B0/D0,SB0/P2/B0/D1,SB0/P2/B0/D2,SB0/P2/B0/D3
    2 1 SB0/P2/B1/D0,SB0/P2/B1/D1,SB0/P2/B1/D2,SB0/P2/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    3 0 SB0/P3/B0/D0,SB0/P3/B0/D1,SB0/P3/B0/D2,SB0/P3/B0/D3
    3 1 SB0/P3/B1/D0,SB0/P3/B1/D1,SB0/P3/B1/D2,SB0/P3/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    8 0 SB2/P0/B0/D0,SB2/P0/B0/D1,SB2/P0/B0/D2,SB2/P0/B0/D3
    8 1 SB2/P0/B1/D0,SB2/P0/B1/D1,SB2/P0/B1/D2,SB2/P0/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    9 0 SB2/P1/B0/D0,SB2/P1/B0/D1,SB2/P1/B0/D2,SB2/P1/B0/D3
    9 1 SB2/P1/B1/D0,SB2/P1/B1/D1,SB2/P1/B1/D2,SB2/P1/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    10 0 SB2/P2/B0/D0,SB2/P2/B0/D1,SB2/P2/B0/D2,SB2/P2/B0/D3
    10 1 SB2/P2/B1/D0,SB2/P2/B1/D1,SB2/P2/B1/D2,SB2/P2/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    11 0 SB2/P3/B0/D0,SB2/P3/B0/D1,SB2/P3/B0/D2,SB2/P3/B0/D3
    11 1 SB2/P3/B1/D0,SB2/P3/B1/D1,SB2/P3/B1/D2,SB2/P3/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    16 0 SB4/P0/B0/D0,SB4/P0/B0/D1,SB4/P0/B0/D2,SB4/P0/B0/D3
    16 1 SB4/P0/B1/D0,SB4/P0/B1/D1,SB4/P0/B1/D2,SB4/P0/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    17 0 SB4/P1/B0/D0,SB4/P1/B0/D1,SB4/P1/B0/D2,SB4/P1/B0/D3
    17 1 SB4/P1/B1/D0,SB4/P1/B1/D1,SB4/P1/B1/D2,SB4/P1/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    18 0 SB4/P2/B0/D0,SB4/P2/B0/D1,SB4/P2/B0/D2,SB4/P2/B0/D3
    18 1 SB4/P2/B1/D0,SB4/P2/B1/D1,SB4/P2/B1/D2,SB4/P2/B1/D3

    Memory Module Groups:
    ————————————————–
    ControllerID GroupID Labels
    ————————————————–
    19 0 SB4/P3/B0/D0,SB4/P3/B0/D1,SB4/P3/B0/D2,SB4/P3/B0/D3
    19 1 SB4/P3/B1/D0,SB4/P3/B1/D1,SB4/P3/B1/D2,SB4/P3/B1/D3

    ======== FRU Status =========
    ————————-
    Fru Operational Status:
    ————————-
    Location Status
    ————————-
    PS0 okay
    PS1 okay
    PS2 okay
    PS3 okay
    FT0 okay
    FT0/FAN3 okay
    FT0/FAN0 okay
    FT0/FAN1 okay
    FT0/FAN2 okay
    FT0/FAN4 okay
    FT0/FAN5 okay
    FT0/FAN6 okay
    FT0/FAN7 okay
    RP0 okay
    RP2 okay
    SB0 ok
    SB0/P0 online
    SB0/P0/B0/D0 okay
    SB0/P0/B0/D1 okay
    SB0/P0/B0/D2 okay
    SB0/P0/B0/D3 okay
    SB0/P0/B1/D0 okay
    SB0/P0/B1/D1 okay
    SB0/P0/B1/D2 okay
    SB0/P0/B1/D3 okay
    SB0/P1 online
    SB0/P1/B0/D0 okay
    SB0/P1/B0/D1 okay
    SB0/P1/B0/D2 okay
    SB0/P1/B0/D3 okay
    SB0/P1/B1/D0 okay
    SB0/P1/B1/D1 okay
    SB0/P1/B1/D2 okay
    SB0/P1/B1/D3 okay
    SB0/P2 online
    SB0/P2/B0/D0 okay
    SB0/P2/B0/D1 okay
    SB0/P2/B0/D2 okay
    SB0/P2/B0/D3 okay
    SB0/P2/B1/D0 okay
    SB0/P2/B1/D1 okay
    SB0/P2/B1/D2 okay
    SB0/P2/B1/D3 okay
    SB0/P3 online
    SB0/P3/B0/D0 okay
    SB0/P3/B0/D1 okay
    SB0/P3/B0/D2 okay
    SB0/P3/B0/D3 okay
    SB0/P3/B1/D0 okay
    SB0/P3/B1/D1 okay
    SB0/P3/B1/D2 okay
    SB0/P3/B1/D3 okay
    SB2 ok
    SB2/P0 online
    SB2/P0/B0/D0 okay
    SB2/P0/B0/D1 okay
    SB2/P0/B0/D2 okay
    SB2/P0/B0/D3 okay
    SB2/P0/B1/D0 okay
    SB2/P0/B1/D1 okay
    SB2/P0/B1/D2 okay
    SB2/P0/B1/D3 okay
    SB2/P1 online
    SB2/P1/B0/D0 okay
    SB2/P1/B0/D1 okay
    SB2/P1/B0/D2 okay
    SB2/P1/B0/D3 okay
    SB2/P1/B1/D0 okay
    SB2/P1/B1/D1 okay
    SB2/P1/B1/D2 okay
    SB2/P1/B1/D3 okay
    SB2/P2 online
    SB2/P2/B0/D0 okay
    SB2/P2/B0/D1 okay
    SB2/P2/B0/D2 okay
    SB2/P2/B0/D3 okay
    SB2/P2/B1/D0 okay
    SB2/P2/B1/D1 okay
    SB2/P2/B1/D2 okay
    SB2/P2/B1/D3 okay
    SB2/P3 online
    SB2/P3/B0/D0 okay
    SB2/P3/B0/D1 okay
    SB2/P3/B0/D2 okay
    SB2/P3/B0/D3 okay
    SB2/P3/B1/D0 okay
    SB2/P3/B1/D1 okay
    SB2/P3/B1/D2 okay
    SB2/P3/B1/D3 okay
    SB4 ok
    SB4/P0 online
    SB4/P0/B0/D0 okay
    SB4/P0/B0/D1 okay
    SB4/P0/B0/D2 okay
    SB4/P0/B0/D3 okay
    SB4/P0/B1/D0 okay
    SB4/P0/B1/D1 okay
    SB4/P0/B1/D2 okay
    SB4/P0/B1/D3 okay
    SB4/P1 online
    SB4/P1/B0/D0 okay
    SB4/P1/B0/D1 okay
    SB4/P1/B0/D2 okay
    SB4/P1/B0/D3 okay
    SB4/P1/B1/D0 okay
    SB4/P1/B1/D1 okay
    SB4/P1/B1/D2 okay
    SB4/P1/B1/D3 okay
    SB4/P2 online
    SB4/P2/B0/D0 okay
    SB4/P2/B0/D1 okay
    SB4/P2/B0/D2 okay
    SB4/P2/B0/D3 okay
    SB4/P2/B1/D0 okay
    SB4/P2/B1/D1 okay
    SB4/P2/B1/D2 okay
    SB4/P2/B1/D3 okay
    SB4/P3 online
    SB4/P3/B0/D0 okay
    SB4/P3/B0/D1 okay
    SB4/P3/B0/D2 okay
    SB4/P3/B0/D3 okay
    SB4/P3/B1/D0 okay
    SB4/P3/B1/D1 okay
    SB4/P3/B1/D2 okay
    SB4/P3/B1/D3 okay
    IB6 ok
    IB6/FAN0 okay
    IB6/FAN1 okay

  6. I would assume that die and ambient temperatures are the temperatures on the CPU chip (die) and within the case.

    Output of prtdiag -v on a Sunblade 1000:


    System Configuration: Sun Microsystems sun4u SUNW,Sun-Blade-1000 (2 X UltraSPARC-III)
    System clock frequency: 150 MHZ
    Memory size: 1GB

    ==================================== CPUs ====================================
    E$ CPU CPU Temperature
    CPU Freq Size Impl. Mask Die Ambient
    --- -------- ---------- ------ ---- -------- --------
    0 750 MHz 8MB US-III 5.4 75 C 26 C
    1 750 MHz 8MB US-III 5.4 74 C 24 C

    ================================= IO Devices =================================
    Bus Freq
    Brd Type MHz Slot Name Model
    --- ---- ---- ---------- -------------------------------- ----------------------
    0 pci 33 0 network-pci108e,abba.11 (network+ SUNW,pci-ce
    0 pci 33 1 SUNW,m64B (display) SUNW,370-4362
    0 pci 66 1 SUNW,qlc-pci1077,2200.1077.4082.+
    0 pci 33 3 SUNW,qlc-pci1077,2200.1077.4082.+
    0 pci 66 4 SUNW,qlc-pci1077,2200.5 (scsi-fc+
    0 pci 33 5 ebus/parallel-ns87317-ecpp (para+
    0 pci 33 5 ebus/serial-sab82532 (serial)
    0 pci 33 5 network-pci108e,1101.1 (network) SUNW,pci-eri
    0 pci 33 5 firewire-pci108e,1102.1001 (fire+
    0 pci 33 6 scsi-pci1000,f.37 (scsi-2)
    0 pci 33 6 scsi-pci1000,f.37 (scsi-2)

    ============================ Memory Configuration ============================
    Segment Table:
    -----------------------------------------------------------------------
    Base Address Size Interleave Factor Contains
    -----------------------------------------------------------------------
    0x0 1GB 4 BankIDs 0,1,2,3

    Bank Table:
    -----------------------------------------------------------
    Physical Location
    ID ControllerID GroupID Size Interleave Way
    -----------------------------------------------------------
    0 0 0 256MB 0
    1 0 1 256MB 1
    2 0 0 256MB 2
    3 0 1 256MB 3

    Memory Module Groups:
    --------------------------------------------------
    ControllerID GroupID Labels
    --------------------------------------------------
    0 0 J0100,J0202,J0304,J0406
    0 1 J0101,J0203,J0305,J0407

    =============================== usb Devices ===============================

    Name Port#
    ------------ -----
    hub 1

    =============================== hub#1 Devices ===============================

    Name Port#
    ------------ -----
    mouse 1
    keyboard 3

    ============================ Environmental Status ============================
    Fan Speeds:
    ----------------------------
    Fan Device Speed
    ----------------------------
    system 23%
    cpu 28%
    power-supply 100%

    ================================ HW Revisions ================================
    ASIC Revisions:
    ---------------
    pci: Rev 4
    pci: Rev 4
    ebus: Rev 1

    System PROM revisions:
    ----------------------
    OBP 4.4.6 2001/11/05 11:18
    POST 4.4.6 2001/11/08 16:17

  7. System Configuration: Sun Microsystems sun4u Sun Fire V890
    System clock frequency: 150 MHz
    Memory size: 24576 Megabytes

    ========================= CPUs ===============================================

    Run E$ CPU CPU
    Brd CPU MHz MB Impl. Mask
    — —– —- —- ——- —-
    A 0, 16 1500 32,0 US-IV+ 2.1
    B 1, 17 1500 32,0 US-IV+ 2.2
    A 2, 18 1500 32,0 US-IV+ 2.1
    B 3, 19 1500 32,0 US-IV+ 2.2

    ========================= Memory Configuration ===============================

    Logical Logical Logical
    MC Bank Bank Bank DIMM Interleave Interleaved
    Brd ID num size Status Size Factor with
    —- — —- —— ———– —— ———- ———–
    A 0 0 1024MB no_status 512MB 8-way 0
    A 0 1 1024MB no_status 512MB 8-way 0
    A 0 2 1024MB no_status 512MB 8-way 0
    A 0 3 1024MB no_status 512MB 8-way 0
    B 1 0 2048MB no_status 1024MB 8-way 1
    B 1 1 2048MB no_status 1024MB 8-way 1
    B 1 2 2048MB no_status 1024MB 8-way 1
    B 1 3 2048MB no_status 1024MB 8-way 1
    A 2 0 1024MB no_status 512MB 8-way 0
    A 2 1 1024MB no_status 512MB 8-way 0
    A 2 2 1024MB no_status 512MB 8-way 0
    A 2 3 1024MB no_status 512MB 8-way 0
    B 3 0 2048MB no_status 1024MB 8-way 1
    B 3 1 2048MB no_status 1024MB 8-way 1
    B 3 2 2048MB no_status 1024MB 8-way 1
    B 3 3 2048MB no_status 1024MB 8-way 1

    ========================= IO Cards =========================

    Bus Max
    IO Port Bus Freq Bus Dev,
    Brd Type ID Side Slot MHz Freq Func State Name Model
    —- —- —- —- —- —- —- —- —– ——————————– ———————-
    I/O PCI 8 B 1 33 33 4,0 ok pci-pci8086,b154.0/network (netw+ PCI-BRIDGE
    I/O PCI 8 B 1 33 33 0,0 ok network-pci100b,35.30 SUNW,pci-ce/pci-bridge
    I/O PCI 8 B 1 33 33 1,0 ok network-pci100b,35.30 SUNW,pci-ce/pci-bridge
    I/O PCI 8 B 1 33 33 2,0 ok scsi-pci1000,b.7/disk (block) device on pci-bridge
    I/O PCI 8 B 1 33 33 2,1 ok scsi-pci1000,b.7/disk (block) device on pci-bridge
    I/O PCI 8 B 0 33 33 5,0 ok SUNW,XVR-600 SUNW,375-3153

    No failures found in System
    ===========================